4.8 MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)
MDIO Registers
The MDIO user command complete interrupt (unmasked) register (USERINTRAW) is shown in Figure 22
and described in Table 21 .
Figure 22. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW)
31 16
Reserved
R-0
15 2 1 0
Reserved USERINTRAW
R-0 R/WC-0
LEGEND: R = Read only; R/WC = Read/Write 1 to clear; - n = value after reset
Table 21. MDIO User Command Complete Interrupt (Unmasked) Register (USERINTRAW) Field
Descriptions
Bit Field Value Description
31-2 Reserved 0 Reserved
1-0 USERINTRAW MDIO User command complete event bits. When asserted, a bit indicates that the previously
scheduled PHY read or write command using that particular USERACCESS register has
completed. Writing a 1 will clear the event and writing 0 has no effect.
SPRU975B – August 2006 Ethernet Media Access Controller (EMAC)/Management Data Input/Output (MDIO) 73